TIOVX User Guide

Safety parameters structure for VPAC VISS. More...

#include <hwa_vpac_viss.h>

Detailed Description

Safety parameters structure for VPAC VISS.

This structure can be used to configure safety-related features such as error event monitoring and status register validation for the VISS module.

The following safety mechanisms can be enabled by setting the individual parameters:

  • enable_reconfig_and_reinit_Reg: Enables the reconfiguration and reinitialization of the registers safety mechanism feature.
  • enable_status_reg_validation: Enables the status register validation safety mechanism feature.
  • enable_readback_config_registers: Enables the readback of configuration registers for safety validation.

Operation modes for safety flags:

  • 0 = disabled: The feature is turned off.
  • 1 = one-shot: The feature operates once per trigger.
  • 2 = continuous: The feature operates continuously until stopped.

Definition at line 578 of file hwa_vpac_viss.h.


The documentation for this struct was generated from the following file: